Skip to content
EPCMap

How energy efficient are homes in EC1M 3 (London, Islington)?

Summary

Average rating

C69

EC1M average: C 72

Homes in EC1M 3 have an average EPC rating of C (69), a little below the EC1M average of C (72). 100% of homes here are flats or maisonettes, and 61% have solid walls with no insulation.

Rated D or worse
39%
EC1M: 26%
Typical yearly energy cost
£857
EPCs since 2021, at prices then
Built before 1930
37%

For landlords: 47% of privately rented homes here are below C (55 homes), the minimum from October 2030. See the 2030 rules

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the EC1M average.

  • Band A, score 92 to 100: 0% of homes; EC1M <1%.
  • Band B, score 81 to 91: 6% of homes; EC1M 23%.
  • Band C, score 69 to 80: 56% of homes; EC1M 51%.
  • Band D, score 55 to 68: 27% of homes; EC1M 19%.
  • Band E, score 39 to 54: 12% of homes; EC1M 6%.
  • Band F, score 21 to 38: 0% of homes; EC1M <1%.
  • Band G, score 1 to 20: 0% of homes; EC1M <1%.

Based on the latest energy performance certificate (EPC) for each of 108 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100. EC1M 3 is a postcode sector: every postcode that starts EC1M 3.

Other postcode sectors in EC1M

EC1M 3 has the 3rd highest average rating of the 5 sectors in EC1M with enough EPCs to show.

What homes here are like

What EPC assessors recorded when they visited homes in EC1M 3.

Main heating

Communal or district heating34%
Gas boiler21%
Oil boiler17%
Other electric heating15%
Electric storage heaters12%

Walls, roof and windows

Solid walls, not insulated61%
Cavity walls, insulated6%
Solid walls, insulated9%
Other walls (timber, system-built or modern)23%
Loft insulation under 100 mm (homes with a loft)50%
Double or triple glazing throughout89%

Ratings by type of home

Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.

Type of homeShare of homesAverage ratingRated D or worse
Flat or maisonette100%C 69EC1M: C 7339%

Typical floor area is the median. Types with fewer than 20 homes here aren't shown.

Privately rented homes and the 2030 standard

Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.

47%

of privately rented homes here are below C (55 homes)

EC1M: 28%

  • 81% of those could reach C with the upgrades listed on their EPC.
  • 0% are rated F or G, below today's minimum of E (EC1M: 0%).

From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK

Upgrades recommended for homes in EC1M 3

Where EC1M 3 differs from the rest of EC1M. For every upgrade and its typical cost, see EC1M.

  • Solid wall insulation (internal or external)

    On 59% of EPCs here (EC1M: 35%). 61% of homes here have solid walls with no insulation.

    Typical cost: £4,000–£14,000
  • Modern storage heaters

    On 23% of EPCs here (EC1M: 8%). 27% of homes here are heated by electricity.

    Typical cost: £1,200–£1,800
  • Double glazing

    On 14% of EPCs here (EC1M: 23%). 11% of homes aren't fully double or triple glazed.

    Typical cost: £3,300–£6,500

With all its recommended upgrades, 87% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £140 a year, at the prices used when each EPC was issued.

Map of EC1M 3 and nearby areas

How EC1M 3 compares with the postcode sectors around it.

EC1A 4, London: C 77EC1A 7, London: C 77EC1A 9, London: C 70EC1M 4, London: D 67EC1M 5, London: C 76EC1M 6, London: D 68EC1M 7, London: C 78EC1N 2, London: C 77EC1N 7, London: C 71EC1N 8, London: C 71EC1R 0, London: C 69EC1R 3, London: C 69EC1R 5, London: C 71EC1V 0, London: C 70EC1V 3, London: C 74EC1V 4, London: C 71EC1V 9, London: C 70EC1Y 0, London: C 70EC1Y 8, London: C 72EC2V 7: not enough EPCs to showEC2Y 5, London: B 81EC2Y 8, London: D 64EC4A 1, London: C 69EC4A 2, London: C 71EC4A 3, London: C 69EC4A 4: not enough EPCs to showEC4M 7, London: D 68EC4M 9, London: C 69EC4N 1: not enough EPCs to showEC4V 4: not enough EPCs to showEC4V 5, London: C 69EC4V 6, London: C 72EC4Y 1, London: C 69EC4Y 7, London: D 64EC4Y 8, London: C 74WC1N 2, London: C 70WC1N 3, London: D 67WC1R 4, London: C 70WC1R 5, London: D 57WC1V 6, London: C 74WC1X 0, London: C 77WC1X 9, London: C 69WC2A 1, London: C 78WC2A 2, London: B 85WC2A 3, London: D 61WC2B 4, London: D 67WC2B 6, London: C 72WC2R 1, London: B 82WC2R 3, London: C 78EC1A 7C 77EC1M 6D 68EC1N 7C 71EC1R 0C 69EC1V 0C 70EC1Y 0C 70EC2Y 8D 64EC4A 1C 69EC4M 7D 68EC4M 9C 69WC1X 0C 77WC2A 2B 85WC2A 3D 61EC1M 3C 69EC1A 7C 77EC1A 9C 70EC1M 4D 67EC1M 6D 68EC1N 2C 77EC1N 7C 71EC1R 0C 69EC1R 3C 69EC1V 0C 70EC1Y 0C 70EC2Y 8D 64EC4A 1C 69EC4A 4EC4M 7D 68EC4M 9C 69WC1R 5D 57WC1X 0C 77WC2A 2B 85WC2A 3D 61EC1M 3C 69
Colour shows each area's average rating. Tap an area to open it. A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 EC1M 3 Not enough EPCs

Bordering postcode sectors

Common questions

What holds energy ratings back in EC1M 3?

About 61% of homes here have solid walls with no insulation, which lose much more heat than insulated walls. 37% were built before 1930. Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

What is a postcode sector?

A postcode sector is the part of a postcode before the last two letters. EC1M 3 covers every postcode that starts EC1M 3, usually a few thousand homes. It's part of the EC1M postcode district.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.