Skip to content
EPCMap

How energy efficient are homes in W7 2 (London, Ealing)?

Summary

Average rating

D64

W7 average: D 67

Homes in W7 2 have an average EPC rating of D (64), a little below the W7 average of D (67). 55% of homes here were built before 1930, and 75% have solid walls with no insulation.

Rated D or worse
63%
W7: 50%
Typical yearly energy cost
£982
EPCs since 2021, at prices then
Built before 1930
55%

For landlords: 55% of privately rented homes here are below C (510 homes), the minimum from October 2030. See the 2030 rules

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the W7 average.

  • Band A, score 92 to 100: 0% of homes; W7 <1%.
  • Band B, score 81 to 91: 6% of homes; W7 13%.
  • Band C, score 69 to 80: 32% of homes; W7 37%.
  • Band D, score 55 to 68: 46% of homes; W7 39%.
  • Band E, score 39 to 54: 14% of homes; W7 9%.
  • Band F, score 21 to 38: 2% of homes; W7 1%.
  • Band G, score 1 to 20: <1% of homes; W7 <1%.

Based on the latest energy performance certificate (EPC) for each of 2,132 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100. W7 2 is a postcode sector: every postcode that starts W7 2.

Other postcode sectors in W7

W7 2 has the lowest average rating of the 3 sectors in W7 with enough EPCs to show.

What homes here are like

What EPC assessors recorded when they visited homes in W7 2.

Main heating

Gas boiler93%
Other electric heating3%
Electric storage heaters2%

Walls, roof and windows

Solid walls, not insulated75%
Cavity walls, not insulated7%
Cavity walls, insulated7%
Solid walls, insulated2%
Other walls (timber, system-built or modern)9%
Loft insulation under 100 mm (homes with a loft)45%
Double or triple glazing throughout77%

Ratings by type of home

Flats usually rate higher than houses because they lose less heat through shared walls, floors and ceilings.

Type of homeShare of homesAverage ratingRated D or worse
Detached house2%D 56W7: D 6082%
Semi-detached house23%D 58W7: D 5987%
Terraced house34%D 63W7: D 6570%
Flat or maisonette42%C 69W7: C 7144%

Typical floor area is the median. Types with fewer than 20 homes here aren't shown.

Privately rented homes and the 2030 standard

Landlords need an EPC rating of at least E to let a home today. From 1 October 2030, privately rented homes in England and Wales will need a C or better, unless the landlord registers an exemption.

55%

of privately rented homes here are below C (510 homes)

W7: 55%

  • 92% of those could reach C with the upgrades listed on their EPC.
  • &lt;1% are rated F or G, below today's minimum of E (W7: <1%).

From homes whose latest EPC was for a private let. A home sold or let differently since may be counted in the wrong group. The 2030 standard will be measured with new EPC metrics, so treat these figures as a guide. Landlord guidance on GOV.UK

Upgrades recommended for homes in W7 2

Where W7 2 differs from the rest of W7. For every upgrade and its typical cost, see W7.

  • Solid wall insulation (internal or external)

    On 75% of EPCs here (W7: 47%). 75% of homes here have solid walls with no insulation.

    Typical cost: £4,000–£14,000
  • Solar panels (PV)

    On 57% of EPCs here (W7: 42%).

    Typical cost: £5,000–£8,000
  • Solar water heating

    On 47% of EPCs here (W7: 34%).

    Typical cost: £4,000–£6,000
  • Cavity wall insulation

    On 8% of EPCs here (W7: 17%). 6% of homes here have unfilled cavity walls.

    Typical cost: £500–£1,500
  • New condensing boiler

    On 23% of EPCs here (W7: 17%).

    Typical cost: £2,200–£3,000

With all its recommended upgrades, 90% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £236 a year, at the prices used when each EPC was issued.

Map of W7 2 and nearby areas

How W7 2 compares with the postcode sectors around it.

TW5 0, Hounslow: D 68TW7 4, Isleworth: D 68TW7 5, Isleworth: C 69TW8 0, Brentford: C 78TW8 8, Brentford: C 75TW8 9, Brentford: C 70TW9 3, Richmond: D 61UB1 2, Southall: D 65UB1 3, Southall: C 72UB2 4, Southall: C 73UB2 5, Southall: D 67UB6 9, Greenford: D 65W13 0, London: C 71W13 8, London: D 66W13 9, London: D 65W5 2, London: C 69W5 3, London: D 66W5 4, London: D 65W5 5, London: D 66W7 1, London: D 68W7 3, London: C 69TW8 9C 70UB1 3C 72UB2 4C 73W13 9D 65W5 4D 65W5 5D 66W7 2D 64TW7 4D 68TW8 9C 70UB1 3C 72UB2 4C 73W13 9D 65W5 4D 65W5 5D 66W7 2D 64
Colour shows each area's average rating. Tap an area to open it. A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 W7 2 Not enough EPCs

Bordering postcode sectors

Common questions

What holds energy ratings back in W7 2?

About 75% of homes here have solid walls with no insulation, which lose much more heat than insulated walls. 55% were built before 1930. Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

What is a postcode sector?

A postcode sector is the part of a postcode before the last two letters. W7 2 covers every postcode that starts W7 2, usually a few thousand homes. It's part of the W7 postcode district.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.